Mostrar el registro sencillo del ítem

Artículo

dc.creatorRomero Morales, Carloses
dc.creatorCalvo Lobo, Césares
dc.creatorNavarro Flores, Emmanueles
dc.creatorMazoteras-Pardo, Victoriaes
dc.creatorGarcía Bermejo, Paulaes
dc.creatorLópez López, Danieles
dc.creatorMartínez-Jiménez, Eva Maríaes
dc.creatorCruz Torres, Blanca de laes
dc.date.accessioned2021-02-15T10:01:17Z
dc.date.available2021-02-15T10:01:17Z
dc.date.issued2020-12-11
dc.identifier.citationRomero Morales, C., Calvo Lobo, C., Navarro Flores, E., Mazoteras-Pardo, V., García Bermejo, P., López López, D.,...,Cruz Torres, B.d.l. (2020). M-mode ultrasound examination of soleus muscle in healthy subjects: intra- and inter- rater reliability study. Healthcare, 8 (4), 1-10.
dc.identifier.issn2227-9032es
dc.identifier.urihttps://hdl.handle.net/11441/104942
dc.description.abstractObjective: M-mode ultrasound imaging (US) reflects the motion of connective tissue within muscles. The objectives of this study were to evaluate inter-rater and intra-rater reliability of soleus muscle measurements between examiners with different levels of US experience in asymptomatic subjects and to investigate the level of soleus muscle isometric activity in two positions (knee extended and knee flexed at 30°). Methods: Thirty volunteers without a history of ankle pain were evaluated with US examinations of the soleus muscle. Each muscle was scanned independently by two evaluators. Muscle at rest thickness, maximal isometric contraction thickness, time and velocity measures were detailed and blinded to the other examiner. Results: Intra- and inter-rater reliability at rest, in maximal isometric contraction thickness, contraction time and contraction velocity measures for both positions (extended and flexed knee) were reported from good to excellent for all outcome measurements. The position with the knee extended reported a statistically significant increase in thickness after motion showing 1.33 ± 0.27 mm for measurements at rest thickness with knee extended versus 1.50 ± 0.29 mm for measurements at end thickness with the knee in flexed position (p = 0.001), as well as 1.31 ± 0.23 mm for rest thickness with the knee in flexed position measurements with respect to 1.34 ± 0.24 mm for maximal isometric contraction thickness with extended knee measurements (p = 0.058). Conclusions: This study found that intra- and inter-examiner reliability of M-mode ultrasound imaging of the soleus muscle was excellent in asymptomatic subjects and the soleus muscle activity was different between the position with the knee extended and the position with the knee flexed.es
dc.formatapplication/pdfes
dc.format.extent10es
dc.language.isoenges
dc.publisherMDPIes
dc.relation.ispartofHealthcare, 8 (4), 1-10.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectUltrasoundes
dc.subjectM-modees
dc.subjectSoleuses
dc.subjectReliabilityes
dc.titleM-mode ultrasound examination of soleus muscle in healthy subjects: intra- and inter- rater reliability studyes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Fisioterapiaes
dc.relation.publisherversionhttps://doi.org/10.3390/healthcare8040555es
dc.identifier.doi10.3390/healthcare8040555es
dc.journaltitleHealthcarees
dc.publication.volumen8es
dc.publication.issue4es
dc.publication.initialPage1es
dc.publication.endPage10es

FicherosTamañoFormatoVerDescripción
M-mode ultrasound examination ...664.1KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional