dc.description.abstractOBJETIVO: Mediante este estudio se pretende determinar los niveles de carga oclusal en estructuras implanto-soportadas en pacientes parcialmente desdentados rehabilitados mediante implantes oseo-integrados cargados con coronas unitarias o ferulizados mediante estructuras de dos o más coronas. MATERIAL Y MÉTODO: Este estudio se ha llevado a cabo sobre una muestra de 104 implantes correspondientes a 25 pacientes en los que se tomaron registros de máxima intecuspidación mediante T Scan. La fuerza relativa soportada por los implantes se clasificó en tres niveles (supraoclusión, normoclusión e infraoclusión) y se realizó un estudio descriptivo. La unidad de estudio fue el implante. RESULTADOS: En nuestra muestra el 38,46% de los implantes se encontraban en normoclusión, un 31,73 % estaban en supraoclusion (sobrecargados), un 26,92% en infraoclusión y, por último, un 2,88% fuera de oclusión (detectada mediante exploración clínica) CONCLUSIONES: En nuestra muestra, la mayoría de los implantes no ejercen sobre la tabla oclusal unos niveles de fuerza dentro del mismo rango que los dientes naturales. El análisis de la oclusión mediante T Scan suministra información objetiva y precisa sobre los niveles de carga de los implantes osteo-integradoses
dc.description.abstractOBJECTIVE: The aim of this study is to determine the occlusal load withstood by osteointegrated implants in patients wearing either free standing restorations or two or more implants linked by a rigid structure MATERIAL AND METHOD: T Scan records were obtained from 25 implant patients. Relative occlusal force was analyzed in 104 osteointegrated implants. Level of force withstood by implants was classified according to occlusal force intensity into three levels: overload, normal load and underload. A descriptive study was performed. RESULTS: In our sample, 38,46 per cent of implants were under normal occlusal forces, 31,73 per cent were overloaded and 26,9 % underloaded. 2,88 per cent of implants were out of occlusion as determined by clinical inspection. CONCLUSIONS: Most implant restorations do not exert the same level of force as natural teeth. T Scan system for digital analysis of occlusion gives precise and objective information on the level of force withstood by osteo-integrated implantses
dc.formatapplication/pdfes
dc.language.isospaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectImplantes dentaleses
dc.subjectOclusión dentales
dc.titleCuantificación de la carga oclusal de implantes osteo-integrados : Estudio clínicoes
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationes
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Estomatologíaes
idus.format.extent28 p.es