dc.creator | Aponte, Juan | es |
dc.creator | Roa Romero, Laura María | es |
dc.creator | Gómez Galán, Juan Antonio | es |
dc.creator | Naranjo Hernández, David | es |
dc.creator | Estudillo-Valderrama, Miguel Ángel | es |
dc.creator | Barbarov-Rostán, Gerardo | es |
dc.creator | Rubia-Marcos, Carlos | es |
dc.date.accessioned | 2016-12-09T18:30:22Z | |
dc.date.available | 2016-12-09T18:30:22Z | |
dc.date.issued | 2014-02-14 | |
dc.identifier.citation | Aponte, J., Roa Romero, L.M., Gómez Galán, J.A., Naranjo Hernández, D., Estudillo-Valderrama, M.Á., Barbarov-Rostán, G. y Rubia-Marcos, C. (2014). Design and Implementation of a Smart Sensor for Respiratory Rate Monitoring. Sensors, 14 (2), 3019-3032. | |
dc.identifier.issn | 1424-8220 | es |
dc.identifier.uri | http://hdl.handle.net/11441/49948 | |
dc.description.abstract | This work presents the design, development and implementation of a smart sensor to monitor the respiratory rate. This sensor is aimed at overcoming the drawbacks of other systems currently available in market, namely, devices that are costly, uncomfortable, difficult-to-install, provide low detection sensitivity, and little-to-null patient-to-patient calibration. The device is based on capacitive sensing by means of an LC oscillator. Experimental results show that the sensor meets the necessary requirements, making feasible the proposed monitoring system with the technology used | es |
dc.description.sponsorship | Ministerio de Ciencia e Innovación y Unión Europea FPA2010-22131-C02-02 | es |
dc.description.sponsorship | Consejo Andaluz de Innovación, Ciencia y Empresa P08-TIC-04069 y P10-TIC- 6311 | es |
dc.format | application/pdf | es |
dc.language.iso | eng | es |
dc.publisher | MDPI | es |
dc.relation.ispartof | Sensors, 14 (2), 3019-3032. | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Capacitive technology | es |
dc.subject | Respiratory rate monitoring | es |
dc.subject | Smart sensor | es |
dc.title | Design and Implementation of a Smart Sensor for Respiratory Rate Monitoring | es |
dc.type | info:eu-repo/semantics/article | es |
dcterms.identifier | https://ror.org/03yxnpp24 | |
dc.type.version | info:eu-repo/semantics/publishedVersion | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.contributor.affiliation | Universidad de Sevilla. Departamento de Ingeniería de Sistemas y Automática | es |
dc.relation.projectID | Universidad de Sevilla.TIC203: Ingenieria Biomedica | es |
dc.relation.publisherversion | http://dx.doi.org/10.3390/s140203019 | es |
dc.identifier.doi | 10.3390/s140203019 | es |
dc.contributor.group | Universidad de Sevilla. TIC203: Ingenieria Biomedica | es |
idus.format.extent | 14 p. | es |
dc.journaltitle | Sensors | es |
dc.publication.volumen | 14 | es |
dc.publication.issue | 2 | es |
dc.publication.initialPage | 3019 | es |
dc.publication.endPage | 3032 | es |
dc.identifier.idus | https://idus.us.es/xmlui/handle/11441/49948 | |
dc.contributor.funder | Ministerio de Ciencia e Innovación (MICIN). España | |
dc.contributor.funder | Junta de Andalucía | |