Mostrar el registro sencillo del ítem

Artículo

dc.creatorMartínez Cepa, Carmen Belénes
dc.creatorZuil Escobar, Juan Carloses
dc.creatorChillón Martínez, Raqueles
dc.creatorJiménez Rejano, José Jesúses
dc.creatorPalomo Toucedo, Inmaculada Concepciónes
dc.date.accessioned2022-02-01T09:57:46Z
dc.date.available2022-02-01T09:57:46Z
dc.date.issued2014
dc.identifier.citationMartínez Cepa, C.B., Zuil Escobar, J.C., Chillón Martínez, R., Jiménez Rejano, J.J. y Palomo Toucedo, I.C. (2014). Intra-observer reliability for measuring first and second toe and metatarsal protrusion distance using palpation-based tests: a test-retest study. Journal of Foot and Ankle Research, 7 (37), 1-6.
dc.identifier.issn1757-1146es
dc.identifier.urihttps://hdl.handle.net/11441/129507
dc.description.abstractBackground: Measurement of first and second metatarsal and toe protrusion is frequently used to explain foot problems using x-rays, osteological measurements or palpation-based tests. Length differences could be related to the appearance of problems in the foot. A test-retest design was conducted in order to establish the intra-rater reliability of three palpation-based tests. Methods: 202 feet of physical therapy students and teachers of the CEU San Pablo University of Madrid, 39 men and 62 women, were measured using three different tests. Data were analysed using SPSS version 15.0. Mean, SD and 95% CI were calculated for each variable. A normal distribution of quantitative data was assessed using the Kolmogorov-Smirnov test. The test-retest intra-rater reliability was assessed using an Intraclass Correlation Coefficient (ICC). The Standard Error Mean (SEM) and the Minimal Detectable Change (MDC) were also obtained. Results: All the ICC values showed a high degree of reliability (Test 1 = 0.97, Test 2 = 0.86 and Test 3 = 0.88) as did the SEM (Test 1 = 0.07, Test 2 = 0.10 and Test 3 = 0.11) and the MDC (Test 1 = 0.21, Test 2 = 0.30 and Test 3 = 0.31). Conclusions: Reliability of measuring first and second metatarsal and toe protrusion using the three palpation-based tests showed a high degree of reliability.es
dc.formatapplication/pdfes
dc.format.extent6es
dc.language.isoenges
dc.publisherSpringer Naturees
dc.relation.ispartofJournal of Foot and Ankle Research, 7 (37), 1-6.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectReproducibility of resultses
dc.subjectAnthropometryes
dc.subjectFootes
dc.titleIntra-observer reliability for measuring first and second toe and metatarsal protrusion distance using palpation-based tests: a test-retest studyes
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Fisioterapiaes
dc.contributor.groupUniversidad de Sevilla. CTS305: Área de Fisioterapiaes
dc.journaltitleJournal of Foot and Ankle Researches
dc.publication.volumen7es
dc.publication.issue37es
dc.publication.initialPage1es
dc.publication.endPage6es

FicherosTamañoFormatoVerDescripción
Intra_observer reliability for ...673.6KbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional