Trabajo Final de Máster (TFM) Characterization of the MCP-PMT R5916U-64 and design of a multi-detector architecture (C-SPAD + MCP-PMT) for the ROA laser station(2026) Mackinlay Hidalgo, Alejandro; Palomo Pinto, Rogelio; Ingeniería ElectrónicaSatellite Laser Ranging (SLR) is the most accurate technique available for determining the orbits of space objects, providing sub-centimetre precision. Its application to non-cooperative targets (space debris without retroreflectors) places extreme demands on the detection chain. The laser station of the Royal Institute and Observatory of the Spanish Navy (ROA), in San Fernando (Cádiz), the only SLR station currently operating in Spain, currently uses a C-SPAD detector (ηq ≈ 20 % at 532 nm) and two EKSPLA lasers: a PL2251C in ILRS mode (30 ps FWHM, 50 mJ per pulse at 10 Hz) for precision ranging of cooperative targets, and an NL317 in SST mode (2.5 J per pulse) for non-cooperative debris tracking. It is this highenergy SST configuration whose radar–laser link budget [1] places small debris at the reliable detection limit at ranges of a few thousand kilometres. This Master’s Thesis is the first step of a multi-detector modernization strategy that will incorporate, in the medium term, a revolver-type mount with three complementary detectors: the current C-SPAD, a Hamamatsu R5916U-64 microchannel plate photomultiplier (MCP-PMT) with GaAsP photocathode—experimentally characterized in this work—, and an n-type Low Gain Avalanche Detector (nLGAD) developed by IMB-CNM-CSIC [2], planned for a later phase. The experimental core of the thesis is the characterization of the MCP-PMT R5916U-64 (S/N BU0050) on the optical bench of the dome calibration area. The work formalizes the electronic, mechanical, optical and safety requirements of the new detection channel; derives the photon budget and the detector damage thresholds —validated with direct manufacturer feedback—; designs the CAEN A1423B + N978 + N605 + Eventech ESST-7 chain with a Hamamatsu C9727 HV supply and the modular Thorlabs optical chain (SM1D12CZ iris + stackable ND filters NE40B-A/NE50A-A + custom M42×1 adapter to the Hamamatsu C10373 housing); and proposes an experimental validation plan structured as a metrology exercise in five progressive phases covering physical installation and chain verification, dark characterization of the detector, metrological characterization of the attenuation subsystem with a pyroelectrc sensor, focal-plane energy measurement against the calibration bench, and the decision and mounting of the additional attenuator required to close the photon budget. The quantitative characterization with laser light —single-photon regime, IRF and G(V ) curve— is explicitly identified as immediate post-thesis continuation work. The plan was executed on unit BU0050 in May–June 2026: F1 was closed in full, F2 in its principal criteria, F3 was executed with a finding that redefined the attenuation strategy, and F4–F5 were reframed and resolved on the bench, culminating in the controlled first exposure of the photocathode. F1 verified the chain end to end with a pulse generator (ESST-7 differential precision <1 ns with a ∼30 ps core; SHV continuity verified). F2 measured the detector thermal dark rate and experimentally validated its temperatura dependence: 0.58 cps at −20 °C and 4.4 cps at +9 °C, on the curve D(T) = 13 · 2(T−25)/10 anchored to the manufacturer’s datasheet within <3 %. The channel operating point was set by a fine threshold scan (N978 gain ×4, threshold −22.0 mV, −3000 V), after diagnosing and resolving two chain pathologies: a faulty connection at the preamplifier input (source of spurious rates of 105–106 cps) and amplifier self-oscillation at gain ×5. Phase F3 metrology additionally measured an effective OD of the ND filters well below nominal (≈4.8 vs. 9.0); a deficit whose cause —saturable absorption under the picosecond pulse (main hypothesis), open-bench measurement uncertainty, or others— remains to be determined and which, as a precaution, redirects the channel attenuation toward reflective elements. As the campaign’s milestone, the detector achieved its first light: with HV at −3000 V and the laser attenuated to 1 %, the anode delivered resolvable photoelectron pulses —from single to multi-photoelectron—without damage, validating the end-to-end operation of the MCP-PMT channel with real photons. In parallel, the photon budget quantifies the improvement of the MCP-PMT (ηq = 43.5 %) over the C-SPAD: a factor of ×2.17 in detected photoelectrons and an extension of the reliable detection range on an SL-16 target from 1477 to 1794 km in SST mode. To close, the thesis proposes the preliminary architecture of the revolver-type multi-detector mount and a continuity roadmap that includes the mechanical integration of the MCP-PMT in the mount, the characterization of the nLGAD once the IMB-CNM-CSIC unit is received, and the software integration of the channel into the Degoras project [3].