dc.identifier.citationCalama-González, C.M., León Rodríguez, Á.L. y Suárez Medina, R.C. (2022). Assessing thermal comfort in the Mediterranean social housing stock through test cells: Comparison of double-skin, externally insulated and non-retrofitted facades. Case Studies in Thermal Engineering, 38 (102369). https://doi.org/10.1016/j.csite.2022.102369.
dc.identifier.issn2214-157Xes
dc.identifier.urihttps://hdl.handle.net/11441/144664
dc.description.abstractClimate change will derive in severe repercussions to the built indoor environment, evidencing the importance of retrofitting buildings. Thus, the improvement of energy efficiency of facades is of the utmost relevance, given its representativeness in the total thermal envelope. The objective of this research is to provide a simultaneous comparison between a ventilated double skin facade and an unretrofitted solution, assessing their impact on thermal comfort of housing units under Mediterranean winter and summer conditions. To do so, on-site monitoring through test cells have been used, analysing different orientations and protocols, under the same weather conditions and with no users’ influence. Comfort results obtained have been compared with an externally insulated facade. Conclusions show that the double skin facade clearly performs better in summer, minimising indoor maximum peak temperatures, especially with outdoor temperatures above 35 °C. Yet, it may lead to indoor overheating during night-time. In winter, the double skin facade reports around 21.3% less comfort hours than an externally insulated facade, performing similarly to an unretrofitted solution towards maximum peak temperatures with outdoor values of 5–20 °C. However, it shows a better thermal performance under minimum peak temperatures, with up to 3 °C difference from the unretrofitted solution.es
dc.formatapplication/pdfes
dc.format.extent17 p.es
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofCase Studies in Thermal Engineering, 38 (102369).
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectHousing stock retrofittinges
dc.subjectTest cellses
dc.subjectMediterranean climatees
dc.subjectOpaque double-skin facadees
dc.subjectIndoor comfortes
dc.titleAssessing thermal comfort in the Mediterranean social housing stock through test cells: Comparison of double-skin, externally insulated and non-retrofitted facadeses
dc.typeinfo:eu-repo/semantics/articlees
dcterms.identifierhttps://ror.org/03yxnpp24
dc.type.versioninfo:eu-repo/semantics/publishedVersiones
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.contributor.affiliationUniversidad de Sevilla. Departamento de Construcciones Arquitectónicas I (ETSA)es
dc.relation.projectIDFEDER 2014-2020es
dc.relation.projectIDUS-138083es
dc.relation.projectIDBIA2017-86383-Res
dc.relation.projectIDFPU17/ 01375es
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S2214157X22006074?via%3Dihubes
dc.identifier.doi10.1016/j.csite.2022.102369es
dc.contributor.groupUniversidad de Sevilla. TEP130: Arquitectura, Patrimonio y Sostenibilidad: Acústica, Iluminación, Óptica y Energíaes
dc.journaltitleCase Studies in Thermal Engineeringes
dc.publication.volumen38es
dc.publication.issue102369es
dc.contributor.funderEuropean Commission (EC). Fondo Europeo de Desarrollo Regional (FEDER)es
dc.contributor.funderMinisterio de Economía y Competitividad (MINECO). Españaes
dc.contributor.funderMinisterio de Educación, Cultura y Deporte (MECD). Españaes
dc.description.awardwinningPremio Trimestral Publicación Científica Destacada de la US. Instituto Universitario de Arquitectura y Ciencias de la Construcción

FicherosTamañoFormatoVerDescripción
Assessing thermal comfort in the ...11.21MbIcon   [PDF] Ver/Abrir  

Este registro aparece en las siguientes colecciones

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como: Attribution-NonCommercial-NoDerivatives 4.0 Internacional